Water Heater Size Calculator: Peak Hour & Flow Demand

Estimate hot-water volume during your busiest hour. Then separately explore instantaneous heating power for a continuous draw.

Calculate your planning estimate

Updates as you type. Every unit is labelled. Change example values to your design data.

Re-enter every volume, flow and rise after switching. US gallons, not Imperial gallons.
Allowed input: 0 to 100. These are calculator bounds, not code limits.
Editable example, not a standard allowance; use hot-water share, not mixed shower volume. Allowed input: 0 to 1000000. These are calculator bounds, not code limits.
Allowed input: 0 to 1000000. These are calculator bounds, not code limits.
Allowed input: 0 to 1000000. These are calculator bounds, not code limits.
Allowed input: 0 to 200. These are calculator bounds, not code limits.

Results

Rounded for display. Estimates are not equipment specifications.

Formula & assumptions

Peak-hour demand = showers × hot volume per shower + other hot volume. Tankless BTU/h ≈ US GPM × 8.33 lb/gal × 60 × ΔT°F.

All defaults are illustrative unless identified as a published chart value. Unit selectors reinterpret values; re-enter equivalent numbers after switching.

Storage heaters: compare first-hour rating

PNNL’s DOE-funded Building America guidance says to compare the storage heater’s first-hour rating with peak-hour demand. First-hour rating includes stored hot water and recovery during the hour; it is not tank size. This tool therefore does not turn a peak-hour volume into a guaranteed tank-gallon recommendation.

Build your busiest hour

Use fixture flow, duration and the hot-water share of mixed water. Include laundry, dishwashing and other draws likely to coincide. The default 15 gallons per shower and 15 other gallons are transparent examples only. Two such showers plus the other usage totals 45 US gallons. Actual usage and inlet water temperature can change the requirement substantially.

Tankless power is a different question

At 3 US gallons per minute and a 70°F rise, the water needs approximately 104,958 BTU/h of thermal output, using 8.33 lb per US gallon and a water heat capacity near 1 BTU/lb·°F. This is not fuel input. Check the manufacturer’s flow-versus-rise curve, coldest inlet condition, minimum activation flow and simultaneous demand. The approximate water properties are for planning, not laboratory metering.

The instantaneous example is not added to peak-hour volume. Changing the unit selector reinterprets the values rather than converting them automatically; labels explain the required units.

Questions about this tool

Is the displayed peak volume the tank size I should buy?

No. Compare it with the product’s first-hour rating, not nominal tank capacity.

Should I enter total mixed shower gallons?

Use the hot-water share at the heater. Mixing at the fixture means it may be lower than total delivered shower volume.

Sources & method references

Reviewed 24 November 2026. References explain methods and limitations; citation does not imply approval or affiliation.

Planning estimates only. Verify dimensions, units, design conditions and manufacturer performance. These tools do not replace ACCA Manual J / Manual D, BS EN 12831, an MCS survey or a qualified system design. Defaults are examples, not industry requirements. HeatCool Lookup is an independent reference site.