BTU/h to kW Converter: Heating Watts & Rate Table
Compare thermal power ratings in BTU/h, kW and watts. The units describe heat transfer, not automatically the electricity a system consumes.
Calculate your planning estimate
Updates as you type. Every unit is labelled. Change example values to your design data.
Results
Rounded for display. Estimates are not equipment specifications.
Formula & assumptions
1 kW ≈ 3,412.141633 BTU/h. 1 BTU/h ≈ 0.29307107 W. 1 kW = 1,000 W.
All defaults are illustrative unless identified as a published chart value. Unit selectors reinterpret values; re-enter equivalent numbers after switching.
Useful heating-rate conversions
| BTU/h | Watts | kW |
|---|---|---|
| 1,000 | 293.1 | 0.293 |
| 3,000 | 879.2 | 0.879 |
| 5,000 | 1,465.4 | 1.465 |
| 10,000 | 2,930.7 | 2.931 |
| 12,000 | 3,516.9 | 3.517 |
| 20,000 | 5,861.4 | 5.861 |
| 24,000 | 7,033.7 | 7.034 |
| 30,000 | 8,792.1 | 8.792 |
BTU/h is not the same as BTU
BTU is an amount of heat energy. BTU/h is the rate of transferring it. A 10,000 BTU/h output is about 2.931 kW of thermal power. If it runs steadily for two hours, it transfers about 5.861 kWh of heat; electricity used depends on the system and its performance. This converter does not turn a bare energy quantity into a power rating.
Use like-for-like ratings
For radiators, compare outputs at the same water and room temperatures. For boilers, distinguish useful output from fuel input. For heat pumps, read the capacity at your outdoor and water temperatures rather than comparing headline labels alone. A heat pump’s thermal output can exceed its electrical input; a kW conversion by itself does not determine COP.
Constants use the International Table BTU (approximately 1,055.05585 joules). Values are calculated at higher precision than the display. Small differences from rounded catalogue values are normal; they do not change the underlying unit relationship.
Questions about this tool
Can I convert a gas bill in BTU directly to kW?
Not without a time period. Convert energy to kWh, or divide the energy by hours before using this rate converter.
Is radiator kW the same as boiler electrical demand?
No. Here kW describes thermal output, not pump, control or compressor electrical consumption.
Sources & method references
Reviewed 24 November 2026. References explain methods and limitations; citation does not imply approval or affiliation.
Planning estimates only. Verify dimensions, units, design conditions and manufacturer performance. These tools do not replace ACCA Manual J / Manual D, BS EN 12831, an MCS survey or a qualified system design. Defaults are examples, not industry requirements. HeatCool Lookup is an independent reference site.