Home / Furnace Size Calculator
Independent tools · Transparent assumptions

Furnace Size Calculator: Heat Output & Input Rating

Start with the heating load your home actually needs, then separate delivered heat from the fuel-input number on a furnace label.

Calculate your planning estimate

Updates as you type. Every unit is labelled. Change example values to your design data.

Allowed input: 0 to 1000000. These are calculator bounds, not code limits.
Changing units changes how the number is interpreted; enter the equivalent value yourself.
AFUE is seasonal, not a guaranteed design-point efficiency. Prefer the maker’s rated input/output pair. Allowed input: 1 to 100. These are calculator bounds, not code limits.

Results

Rounded for display. Estimates are not equipment specifications.

Formula & assumptions

Delivered output = design heating load. Illustrative fuel input = output ÷ (efficiency / 100).

All defaults are illustrative unless identified as a published chart value. Unit selectors reinterpret values; re-enter equivalent numbers after switching.

How to use the result

Enter a design heating load from a room-by-room calculation, not the input rating of an old appliance. The primary result is the delivered output required at the outdoor design temperature. The second result is only a way to understand input versus output labels. Compare published rated output directly whenever it is available.

The default 42,000 BTU/h is an example, not an estimate for your home. At an illustrative 95% delivered/input ratio, it corresponds to about 44,211 BTU/h input. That does not mean a unit with a matching nominal label has suitable minimum output, airflow or altitude performance.

Why floor area is not enough

Two homes with the same floor area can have very different exterior areas, glazing, air leakage and local design temperatures. Insulation R-values and duct losses matter too. A fixed BTU-per-square-foot chart hides these differences; this page deliberately does not invent climate-zone multipliers or call them ACCA guidance.

Before selecting equipment

Ask for a formal ACCA Manual J load calculation and the manufacturer’s output data, including any altitude derating. Check minimum modulation, temperature rise, blower capability and the adopted local requirements. An oversized furnace can cycle frequently; rounding the arithmetic far upward is not a substitute for selection design.

Questions about this tool

Can I divide heat load by AFUE?

It illustrates the distinction between fuel input and delivered heat, but AFUE is seasonal. Use the manufacturer’s rated output for actual selection.

Is this an ACCA Manual J calculation?

No. It converts a heating load you supply. Obtain a proper load calculation before specifying equipment.

Sources & method references

Reviewed 24 November 2026. References explain methods and limitations; citation does not imply approval or affiliation.

Planning estimates only. Verify dimensions, units, design conditions and manufacturer performance. These tools do not replace ACCA Manual J / Manual D, BS EN 12831, an MCS survey or a qualified system design. Defaults are examples, not industry requirements. HeatCool Lookup is an independent reference site.