UK Radiator Size Calculator: Watts, BTU/h & ΔT50

Calculate the catalogue output needed when your heating water runs cooler than the ΔT50 rating condition. Start with a room heat loss, not a floor-area guess.

Calculate your planning estimate

Updates as you type. Every unit is labelled. Change example values to your design data.

Allowed input: 0 to 1000000. These are calculator bounds, not code limits.
Allowed input: 1 to 100. These are calculator bounds, not code limits.
Allowed input: 1 to 100. These are calculator bounds, not code limits.
Allowed input: 0 to 50. These are calculator bounds, not code limits.
1.3 is an illustrative average; prefer the maker’s correction table or product exponent. Allowed input: 0.5 to 2. These are calculator bounds, not code limits.

Results

Rounded for display. Estimates are not equipment specifications.

Formula & assumptions

Operating ΔT = (flow + return)/2 − room. Output factor = (ΔT/50)^n. Required ΔT50 rating = room loss ÷ factor.

All defaults are illustrative unless identified as a published chart value. Unit selectors reinterpret values; re-enter equivalent numbers after switching.

Why the temperature rating matters

A radiator’s advertised output is only meaningful with its rating temperatures. A common ΔT50 reference uses 75°C flow, 65°C return and 20°C room air: mean water temperature 70°C, or 50 K above the room. If mean water temperature falls, the same radiator emits less heat.

Worked low-temperature example

At 55/45/20°C, operating ΔT is 30 K. With exponent 1.3, the output factor is about 0.515. A room needing 1,000 W therefore needs about 1,943 W of ΔT50 catalogue output, roughly 6,629 BTU/h. This power-law approximation is close to, but not identical with, every manufacturer’s tabulated factor. Use that table for a specific product.

Operating ΔTApproximate factor, n=1.3
200.304
250.406
300.515
400.748
501.000

Do not multiply the wrong way

To find what an existing radiator gives at lower water temperature, multiply its catalogue output by the factor. To find the catalogue output required for a known room heat loss, divide by the factor, as this tool does. A factor below one requires a larger catalogue rating, not a smaller one.

Pipework, flow rate, balancing, available wall space, valves and comfort requirements still need checking. This is not a product recommendation. If mean water temperature is no warmer than the room, the tool rejects the case rather than returning an infinite radiator size.

Questions about this tool

Is the exponent always 1.3?

No. It is an illustrative average. Use the product’s published exponent or temperature correction table.

Does BTU on a UK radiator label mean energy?

Radiator output is a rate, usually BTU/h, even when a label shortens it to BTU. This tool uses BTU per hour.

Sources & method references

Reviewed 24 November 2026. References explain methods and limitations; citation does not imply approval or affiliation.

Planning estimates only. Verify dimensions, units, design conditions and manufacturer performance. These tools do not replace ACCA Manual J / Manual D, BS EN 12831, an MCS survey or a qualified system design. Defaults are examples, not industry requirements. HeatCool Lookup is an independent reference site.